亚洲欧洲国产视频-亚洲欧洲国产经精品香蕉网-亚洲欧洲国产成人精品-亚洲欧性色美精品suv-亚洲欧美综合在线观看-亚洲欧美综合一区二区三区四区

歡迎光臨深圳市鑫博恒業科技有限公司網站!
全國服務咨詢熱線:

13823144468

產品展示 / products 您的位置:網站首頁 > 產品展示 > > 美國omega流量計 > 美國omega FMA6526ST流量計

美國omega FMA6526ST流量計

簡要描述:美國omega FMA6526ST流量計,美國omega流量儀表 一手貨源,優勢批發,是值得信賴的流量儀表.

  • 產品型號:
  • 廠商性質:代理商
  • 更新時間:2024-04-09
  • 訪  問  量:2003
詳情介紹

美國omega FMA6526ST流量計

質量流量控制器,采用RS485標準,帶報警功能
FMA6500 Series
質量流量控制器,采用RS485標準,帶報警功能
Digital and Analog Modes Operate Simultaneously 
Programmable Flow Configurations 
RS485 Standard, Multi-Drop Capability of Up to 256 units 
Stores Calibration Data for Up to 10 Gases 
Totalizer Indicates Total Gas Quantity 
Alarm Limits for High and Low Gas Flow 
Conversion Factors for Up to 256 Gases 
Autotune Function for Optimum Control Response 
Self Diagnostic Tests
Microprocessor driven digital flow controllers allow one to program, record, and analyze flow rates of various gases with a computer via an RS485 interface (optional RS232 is available). Controllers can be programmed for various control functions including flow setpoint, totalizer, stop totalizer, read totalizer, totalizer from preset flow, stop at preset total, auto zero, and more.
Principles of Operation
Metered gases are divided into two laminar flow paths, one through the primary flow conduit, and the other through a capillary sensor tube. Both flow conduits are designed to ensure laminar flows and, therefore, the ratio of their flow rates is constant. Two precision temperature sensing windings on the sensor tube are heated, and when flow takes place, gas carries heat from the upstream to the downstream windings. The resultant temperature differential is proportional to the change in resistance of the sensor windings. A Wheatstone bridge design is used to monitor the temperature dependent resistance gradient on the sensor windings which is linearly proportional to the instantaneous rate of flow. The output of the Wheatstone bridge is converted to digital format with a 12 Bit ADC (analog to digital converter). An on-board microprocessor and nonvolatile memory store all calibration factors and directly control a proportional electromagnetic valve. The digital closed loop control system continuously compares the mass flow output with the selected flow rate. Deviations from the setpoint are corrected by compensating valve adjustments, with PID algorithm thus maintaining the desired flow parameters with a high degree of accuracy. Output signals of 0 to 5 Vdc or 4 to 20 mA are generated indicating mass molecular based flow rates of the metered gas.
Interface
The digital interface operates via RS485 (optional RS232) and provides access to applicable internal data including FLOW SETPOINT, ACTUAL FLOW, ZERO ADJUSTMENTS, and LINEARIZATION TABLE ADJUSTMENTS. The analog interface provides 0 to 5 Vdc, 0 to 10 Vdc and 4 to 20 mA inputs and outputs.
Auto Zero
The FMA6500 automatically nulls the sensor zero offset whenever the flow setpoint is below 2% of full scale. To accommodate this feature the control valve must fully close under that condition. Provisions are made to either disable, force or store the current auto zero via digital commands.
Totalizer
The firmware for the FMA6500 provides functions to register total gas quantity. The total mass of gas is calculated by integrating the actual gas flow rate with respect to time. Digital interface commands are provided to: SET the totalizer to ZERO; START /STOP totalizing the flow; READ the totalizer; START the totalizer at a preset flow STOP the flow at a preset total.
Multi-Gas Calibration
The FMA6500 is capable of storing primary calibration data for up to 10 gases. This feature allows the same FMA6500ST to be calibrated for multiple gases while maintaining the rated accuracy on each.
Conversion Factors
Conversion factors for up to 256 gases are stored in the FMA6500. Conversion factors may be applied to any of the ten gas calibrations via digital interface commands.
Flow Alarms
High and Low gas flow ALARM limits are programmed using the digital interface. Alarm conditions are reported via the digital interface or can activate the contact closure outputs.
Programmable Flow
OMEGA software supports programmable flow modes, allowing execution of custom programming of up to ten steps. Various flow configurations include ramping, linearized increasing and decreasing modes.
Autotune
The AUTOTUNE function allows the FMA6500 to automatically optimize control response for the gas under actual process conditions. During the AUTOTUNE process, the instrument adjusts PID gains for optimum step response and determine key control valve characteristics (only available on units with less than 80 L/min maximum flow).
Contact Closure
Two sets of dry contact relay outputs are provided to actuate user supplied equipment. These are programmable via the digital interface such that the relays can be made to switch when a specified event occurs (e.g. when a low or high flow alarm limit is exceeded or when the totalizer reaches a specified value).
Valve Override
Means are provided to force the control valve fully open (purge) or fully closed via either the analog or digital interfaces.
Self Diagnostics
Whenever power is first applied, the FMA6500 runs a series of SELF DIAGNOSTIC TESTS to ensure that it is in optimum working condition.
Engineering Units
The flow setpoint, measured gas flow and associated totalizer data is scaled directly in engineering units via digital interface commands. The following units of measure are supported: % of FS, mL/min, mL/hr, scfm, scfh, sL/min, sL/hr, lbs/hr, lbs/min, and one user defined unit of measure.
Leak Integrity
1 x 10-9 smL/sec of Helium maximumto the outside environment.
Balanced Power Supply
The FMA6500 operates on ±15 Vdc. The current requirements for the positive and negative power supplies are balanced such that the current in the power supply common connection is minimized. Maximum power consumption is 13.5 watts at ±15 Vdc.
FMA6500 Series Transducers should not be used for monitoring Oxygen gas unless specifically cleaned and prepared for such application. See ordering instructions below.
SPECIFICATIONS
Accuracy (including linearity): 15 to 25°C (59 to 77°F) and 0.7 to 4 bar (10 to 60 psia): ±1% of FS, 0 to 50°C (32 to 122°F) and 0.3 to 10 bar (5 to 150 psia): ±2% of FS, ±1% of FS at a specific temperature and pressure with special calibration
Repeatability: ±0.15% FS
Turndown Ratio: 50:1
Response Time: 0.6 to 1.0 s to within ±2% of setpoint over 20% to 100% FS
Temperature Coefficient: 0.05% of full scale/°C or better
Pressure Coefficient: 0.01% FS/psi (0.07 bar) or better
Leak Integrity: 1 x 10-9 smL/sec Helium maximum to the outside environment
Optimum Gas Pressure: 1.73 bar (25 psig)
Max Gas Pressure: 34.5 bar (500 psig)
Max Diff. Pressure: 3.4 bar (50 psig) for up to 10 LPM, 2.8 bar (40 psig) for 15 LPM and greater
Gas and Ambient Temp: 5 to 50°C (41 to 122°F)
Output Signals: Linear 0 to 5 Vdc (2000 Ω min load impedance); 0 to 10 Vdc (4000 Ω min impedance); 4 to 20 mA optional (0 to 500 Ω loop resistance)
Communication Interface: RS485, standard; RS232, optional
Transducer Input Power: ±15 Vdc, 450 mA maximum
Wetted Parts: 316 stainless steel, 416 stainless steel, FKM O-rings; Neoprene or Perfluoroelastomer O-rings optional
Connections: Standard 1/4" compression fittings up to 30 LPM models; for 60 LPM models and greater: 3/8" compression fittings
Circuit Protection: Circuit boards have built-in polarity reversal protection; resettable fuses provide power input protection
Calibration Options: Standard 10-point NIST calibration optional up to 9 additional 10-point calibrations may be ordered for an additional charge

產品型號/產品描述
Controller: Max Flow and Compression Fitting Connection
FMA6502ST 10 sccm 1/4"
FMA6504ST 20 sccm 1/4"
FMA6506ST 50 sccm 1/4"
FMA6508ST 100 sccm 1/4"
FMA6510ST 200 sccm 1/4"
FMA6512ST 500 sccm 1/4"
FMA6514ST 1 SLPM 1/4"
FMA6516ST 2 SLPM 1/4"
FMA6518ST 5 SLPM 1/4"
FMA6520ST 10 SLPM 1/4"
FMA6523ST 15 SLPM 1/4"
FMA6524ST 20 SLPM 1/4"
FMA6526ST 30 SLPM 1/4"
FMA6528ST 50 SLPM 1/4"
FMA6540ST 60 SLPM 3/8"
FMA6541ST 80 SLPM 3/8"
FMA6542ST 100 SLPM 3/8"
Accessories
FMA65-C Replacement cable 25 pin D-conn with 1.8 m (6') wire, branch to power supply
FMA65PWC Power supply with 25 pin female D-conn 110 Vac (±15 Vdc) branch 1.8 m (6') wire to computer port stripped
FMA65PWA Power supply with 25 pin female D-conn 110Vac (±15 Vdc) branch 1.8 m (6') wire to analog interface
FMA65EPWC European power supply with 25 pin female D-conn 230 Vac (±15 Vdc) branch 1.8 m (6') wire to computer port stripped
FMA65UKPWC UK power supply with 25 pin female D-conn 230 Vac (±15 Vdc) branch 1.8 m (6') wire to computer port stripped
FMA65-C15 25 pin D-conn with 1.8 m (6') wire to 15 pin DM, branch 1.8 m (6'), wire to computer port stripped
注釋: Comes complete with operator’s manual, software, cable (FMA65-C), and NIST Certificate. Power supply sold separay.
** Flow ranges specified are for nitrogen or air at 20 psig inlet (up to 50 SLM) or 25 psig inlet (60 to 100 SLM units) and 0 psig outlet.
For custom calibration add suffix "-(*) to the model number, no additional cost. Replace the * in the model number with the gas or gasses and inlet/outlet pressures.
Calibrations done at ambient (20C/70F) temperature only.
To replace the standard RS485 communications, add suffix "-RS232" to the model number, no additional cost.
For a 4 to 20 mA output, add suffix "-I" to the model number, no additional cost.
To substitute Perflouoroelastomer O-Rings for the standard FKM, add suffix "-K" to the model number, add $364 to price.
For Oxygen cleaned units, add suffix "O2CLEAN" to model number; add $125 to price.
(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)

 美國omega FMA6526ST流量計 

相關產品:

FMA3301ST質量流量計 美國omega



留言詢價

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7
技術支持:化工儀器網   sitemap.xml   管理登陸
© 2025 版權所有:深圳市鑫博恒業科技有限公司( m.16782.com.cn)   備案號:粵ICP備09037369號   
主站蜘蛛池模板: 四虎免费看| 摸咪网在线影院在线观看| 日本黄色高清视频网站| 国产精品极品美女自在线 | 午夜无码片在线观看影院| 天天操丝袜| 亚洲精品一区波多野结衣| www.日日爱| 男人扒开女人下身添| 本站只有精品| 日本精品久久久久中文字幕 1| 513热点网| 香港论理午夜电影网| 国产趴着打光屁股sp抽打| www.尤物| 特黄特色大片免费视频大全| 99视频在线免费观看| 日本高清无吗| 日本四虎影视| 午夜电影三级还珠格格| 国产成+人+综合+亚洲不卡| 国产精品第四页| 牧教师在线观看| 国产精品自产拍在线观看2019| 久久精品国产免费播放| 国产精品九九久久一区hh| 美女mm131爽爽爽久久| 青春娱乐国产分类精品二| 精品区2区3区4区产品乱码9| 久久精品国产欧美日韩99热| 欧美成人tv在线观看免费| 久久福利影院| 日韩网站在线观看| 欧美人禽杂交在线视频| 青青青在线免费| 香港论理午夜电影网| 男人女人日批| 极品奶妈漫画| 国产大神91一区二区三区| 天天操网| 亚洲高清无码在线 视频|